Stainless-steel submersible sensors
for continuous measurement
of water levels
Output | analogue |
Measurement accuracy deviation | 0,5% FSO |
IP rating | IP 68 |
Stainless-steel submersible sensors
for continuous measurement
of water levels
Output | analogue |
Measurement accuracy deviation | 0,5% FSO |
IP rating | IP 68 |
Stainless-steel submersible sensors for continuous measurement of water levels and levels of clean or slightly contaminated liquids
Output | analogue |
Measurement accuracy deviation | 0,5% FSO |
IP rating | IP 68 |
Stainless-steel submersible probes for continuous measurement of water levels and levels of clean or slightly contaminated liquids
Output | analogue |
Measurement accuracy deviation | 0,1% FSO |
IP rating | IP 68 |
Stainless-steel submersible probes for continuous measurement of water levels and levels of clean or slightly contaminated liquids
Output | Modbus/RTU |
Measurement accuracy deviation | 0,1% FSO |
IP rating | IP 68 |
Ultrasonic display probes for continuous measurement of levels of liquids and selected loose materials
Output | Modbus/analogue |
Measurement accuracy deviation | 0,15% FSO |
IP rating | IP67 |
Ultrasonic probes for continuous level measurement of levels of liquids and selected loose materials
Output | Modbus/analogue |
Measurement accuracy deviation | 0,15% ,0,2%, 0,3%FSO |
IP rating | IP67 |
Ultrasonic 6-metre-range
sensors
Output | analogue |
Measurement accuracy deviation | 0,5% FSO |
IP rating | IP67 |
Ultrasonic 8-metre-range sensors
Output | analogue |
Measurement accuracy deviation | 0,2% FSO |
IP rating | IP67 |
Ultrasonic 3-metre-range sensors
Output | Modbus |
Measurement accuracy deviation | 0,1% FSO |
IP rating | IP67 |
All-purpose low-pressure industrial
sensors
Output | analogue |
Measurement accuracy deviation | 0,5% FSO |
IP rating | IP65 |
All-purpose low-pressure industrial sensors (EXCLUDING cases when a medium – the substance to be measured – is chemically incompatible with stainless steel)
Output | analogue |
Measurement accuracy deviation | 0,35; 0,25; 0,1% FSO |
IP rating | IP67 |
All-purpose intelligent high-pressure industrial sensors (EXCLUDING cases when a medium is chemically incompatible with stainless steel)
Output | analogue |
Measurement accuracy deviation | 0,1% FSO |
IP rating | IP67 |
All-purpose intelligent high-pressure industrial sensors (INCLUDING cases when a medium is chemically incompatible with stainless steel)
Output | Modbus/RTU |
Measurement accuracy deviation | 0,×1 FSO |
IP rating | IP67 |
Rotating display pressure sensors
up to 85°C
Output | analogue |
Measurement accuracy deviation | 0,5% FSO |
IP rating | IP65 |
Compact resistant pressure sensors
up to 125°C
Output | analogue |
Measurement accuracy deviation | 0,25 % FSO |
IP rating | IP67 |
Two-axis tilt/inclination sensors
Output | Analogue |
Measurement accuracy deviation | 0,5% FSO |
IP rating | IP68 |
Weather stations
Output | ModBus |
Measured parameters | • Air temperature • Real-feel temperature • Dew point • Relative humidity barometric pressure • Wind speed • Gusts of wind • Wind direction • Sunrise/Sunset • Precipitation amounts |
Ammonia leak detector – NH3 GABA 2S23
Output | Digital |
Signalisation Concentration level | Level I 250ppm Level II 500ppm |
IP rating | IP54 |
Toxic gas leak detector – CHLORINE – CL2 GABA 2S24
Output | Digital |
Signalisation Concentration level | Level I >3mg /m3 Level II >6mg /m3 |
IP rating | IP54 |
Carbon monoxide leak detector – CO GABA 2S22
Output | Digital |
Signalisation Concentration level | Level I >0,005% Level II >0,013% |
IP rating | IP54 |
Digital vibration sensors
Output | Digital |
Measurement accuracy deviation | 0,00002g |
IP rating | IP50 |
Analogue vibration sensors
Output | 4-20 mA |
Measurement accuracy deviation | 5% |
IP rating | IP67 |